Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content

Vanadium dust

Synonyms & Trade Names
Divanadium pentoxide dust, Vanadic anhydride dust, Vanadium oxide dust, Vanadium pentaoxide dust
CAS No.
1314-62-1
RTECS No.
YW2450000
DOT ID & Guide
2862 151
Formula
V₂O₅
Conversion
IDLH
35 mg/m3 (as V)
See: vandust
Exposure Limits
NIOSH REL
C 0.05 mg V/m3 [15-minute] [*Note: The REL applies to all vanadium compounds except Vanadium metal and Vanadium carbide (see Ferrovanadium dust).]
OSHA PEL
C 0.5 mg V2O5/m3 (resp) See Appendix G
Measurement Methods
NIOSH 7300 , 7301 , 7303 , 7504 , 9102;
OSHA ID185
See: NMAM or OSHA Methods
Physical Description
Yellow-orange powder or dark-gray, odorless flakes dispersed in air.
Molecular Weight
181.9
Boiling Point
3182°F (Decomposes)
Melting Point
1274°F
Solubility
0.8%
Vapor Pressure
0 mmHg (approx)
Ionization Potential
NA
Specific Gravity
3.36
Flash Point
NA
Upper Exposive Limit
NA
Lower Explosive Limit
NA
Noncombustible Solid, but may increase intensity of fire when in contact with combustible materials.
Incompatibilities & Reactivities
Lithium, chlorine trifluoride
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
irritation eyes, skin, throat; green tongue, metallic taste, eczema; cough; fine rales, wheezing, bronchitis, dyspnea (breathing difficulty)
Target Organs
Eyes, skin, respiratory system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH (as V)

Up to 0.5 mg/m3:
(APF = 10) Any air-purifying respirator with an N100, R100, or P100 filter (including N100, R100, and P100 filtering facepieces) except quarter-mask respirators.
Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*

Up to 1.25 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*

Up to 2.5 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 35 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   MEDICAL TESTS: 0240
TOP