1,2-Dibromo-3-chloropropane
Synonyms & Trade Names
1-Chloro-2,3-dibromopropane, DBCP, DibromochloropropanePhysical Description
Dense yellow or amber liquid with a pungent odor at high concentrations. [pesticide] [Note: A solid below 43°F.]Molecular Weight
236.4Boiling Point
384°FFreezing Point
43°FSolubility
0.1%Vapor Pressure
0.8 mmHgIonization Potential
?Specific Gravity
2.05Flash Point
(oc) 170°FUpper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Chemically-active metals such as aluminum, magnesium & tin alloys [Note: Corrosive to metals.]Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, nose, throat; drowsiness; nausea, vomiting; pulmonary edema; liver, kidney injury; sterility; [potential occupational carcinogen]Target Organs
Eyes, skin, respiratory system, central nervous system, liver, kidneys, spleen, reproductive system, digestive systemCancer Site
[in animals: cancer of the nasal cavity, tongue, pharynx, lungs, stomach, adrenal & mammary glands]Personal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated/Daily
Remove:When wet or contaminated
Change:Daily
Provide:Eyewash, Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
At concentrations above the NIOSH REL, or where there is no REL, at any detectable concentration:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division