Isophorone
Synonyms & Trade Names
Isoacetophorone, 3,5,5-Trimethyl-2-cyclohexenone, 3,5,5-Trimethyl-2-cyclo-hexen-1-onePhysical Description
Colorless to white liquid with a peppermint-like odor.Molecular Weight
138.2Boiling Point
419°FFreezing Point
17°FSolubility
1%Vapor Pressure
0.3 mmHgIonization Potential
9.07 eVSpecific Gravity
0.92Flash Point
184°FUpper Exposive Limit
3.8%Lower Explosive Limit
0.8%Incompatibilities & Reactivities
Oxidizers, strong alkalis, aminesExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
irritation eyes, nose, throat; headache, nausea, dizziness, lassitude (weakness, exhaustion), malaise (vague feeling of discomfort), narcosis; dermatitis; In Animals: kidney, liver damageTarget Organs
Eyes, skin, respiratory system, central nervous system, liver, kidneysPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
Provide:Eyewash
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
Up to 40 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 10) Any supplied-air respirator*
Up to 100 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)*
Up to 200 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)*
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus