1-Hexadecanethiol
Synonyms & Trade Names
Cetyl mercaptan, Hexadecanethiol-1, n-Hexadecanethiol, Hexadecyl mercaptanExposure Limits
NIOSH REL
C 0.5 ppm (5.3 mg/m3) [15-minute]OSHA PEL
nonePhysical Description
Colorless liquid or solid (below 64-68°F) with a strong odor.Molecular Weight
258.5Boiling Point
?Freezing Point
64-68°FSolubility
InsolubleVapor Pressure
0.1 mmHgIonization Potential
?Specific Gravity
0.85Flash Point
215°FUpper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Oxidizers, strong acids & bases, alkali metals, reducing agentsExposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, respiratory system; headache, dizziness, lassitude (weakness, exhaustion), cyanosis, nausea, convulsionsTarget Organs
Eyes, skin, respiratory system, central nervous system, bloodPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
Up to 5 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)
(APF = 10) Any supplied-air respirator
Up to 12.5 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)
Up to 25 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division