Hafnium
Synonyms & Trade Names
Celtium, Elemental hafnium, Hafnium metalExposure Limits
NIOSH REL
TWA 0.5 mg/m3 [*Note: The REL also applies to other hafnium compounds (as Hf).]OSHA PEL
TWA 0.5 mg/m3 [*Note: The PEL also applies to other hafnium compounds (as Hf).]Physical Description
Highly lustrous, ductile, grayish solid.Molecular Weight
178.5Boiling Point
8316°FMelting Point
4041°FSolubility
InsolubleVapor Pressure
0 mmHg (approx)Ionization Potential
NASpecific Gravity
13.31Flash Point
NAUpper Exposive Limit
NALower Explosive Limit
NAIncompatibilities & Reactivities
Strong oxidizers, chlorineExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
In Animals: irritation eyes, skin, mucous membrane; liver damageTarget Organs
Eyes, skin, mucous membrane, liverPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated/Daily
Remove:When wet or contaminated
Change:Daily
Provide:Eyewash, Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 2.5 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.
Up to 5 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 12.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*
Up to 25 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 50 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source:
- National Institute for Occupational Safety and Health (NIOSH) Education and Information Division