Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content

2-Ethoxyethyl acetate

Synonyms & Trade Names
Cellosolve® acetate, EGEEA, Ethylene glycol monoethyl ether acetate, Glycol monoethyl ether acetate
CAS No.
111-15-9
RTECS No.
KK8225000
DOT ID & Guide
1172 129
Formula
CH₃COOCH₂CH₂OC₂H₅
Conversion
1 ppm = 5.41 mg/m3
IDLH
500 ppm
See: 111159
Exposure Limits
NIOSH REL
TWA 0.5 ppm (2.7 mg/m3) [skin]
OSHA PEL
TWA 100 ppm (540 mg/m3) [skin]
Measurement Methods
NIOSH 1450;
OSHA 53
See: NMAM or OSHA Methods
Physical Description
Colorless liquid with a mild odor.
Molecular Weight
132.2
Boiling Point
313°F
Freezing Point
-79°F
Solubility
23%
Vapor Pressure
2 mmHg
Ionization Potential
?
Specific Gravity
0.98
Flash Point
124°F
Upper Exposive Limit
?
Lower Explosive Limit
1.7%
Class II Combustible Liquid: Fl.P. at or above 100°F and below 140°F.
Incompatibilities & Reactivities
Nitrates; strong oxidizers, alkalis & acids
Exposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contact
Symptoms
irritation eyes, nose; vomiting; kidney damage; paralysis; In Animals: reproductive, teratogenic effects
Target Organs
Eyes, respiratory system, gastrointestinal tract, reproductive system, hematopoietic system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:No recommendation
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Water flush promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 5 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 10) Any supplied-air respirator*

Up to 12.5 ppm:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)*

Up to 25 ppm:
(APF = 50) Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s)
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s)*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 500 ppm:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode*

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0364
TOP