Skip directly to search Skip directly to A to Z list Skip directly to page options Skip directly to site content

DICAMBA

ICSC: 0139

3,6-Dichloro-o-anisic acid
3,6-Dichloro-2-methoxybenzoic acid
C8H6Cl2O3
Molecular mass: 221.0
ICSC # 0139
CAS # 1918-00-9
RTECS # DG7525000
EC # 607-043-00-X
October 20, 2005 Validated
Fi, review at IHE: 10/09/89

TYPES OF HAZARD/ EXPOSURE

ACUTE HAZARDS/ SYMPTOMS

PREVENTION

FIRST AID/
FIRE FIGHTING

FIRE Not combustible. Liquid formulations containing organic solvents may be flammable. Gives off irritating or toxic fumes (or gases) in a fire.

In case of fire in the surroundings: use appropriate extinguishing media.
EXPLOSION


EXPOSURE
PREVENT DISPERSION OF DUST! AVOID EXPOSURE OF ADOLESCENTS AND CHILDREN!

•INHALATION Cough. Sore throat.
Local exhaust or breathing protection.
Fresh air, rest. Refer for medical attention.
•SKIN Redness. Pain.
Protective gloves.
Remove contaminated clothes. Rinse and then wash skin with water and soap.
•EYES Redness. Pain. Blurred vision.
Safety goggles.
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor.
•INGESTION Nausea. Vomiting. Weakness. Convulsions.
Do not eat, drink, or smoke during work. Wash hands before eating.
Rinse mouth. Refer for medical attention.

SPILLAGE DISPOSAL

STORAGE

PACKAGING & LABELLING

Do NOT let this chemical enter the environment. Personal protection: P2 filter respirator for harmful particles. Sweep spilled substance into containers; if appropriate, moisten first to prevent dusting. Carefully collect remainder, then remove to safe place.
Store in an area without drain or sewer access. Separated from food and feedstuffs .
Do not transport with food and feedstuffs.
Note: A
Xn symbol
R: 22-41-52/53
S: 2-26-61
ICSC: 0139 Prepared in the context of cooperation between the International Programme on Chemical Safety & the Commission of the European Communities (C) IPCS CEC 1994. No modifications to the International version have been made except to add the OSHA PELs, NIOSH RELs and NIOSH IDLH values.

DICAMBA

ICSC: 0139

I

M

P

O

R

T

A

N

T


D

A

T

A

PHYSICAL STATE; APPEARANCE:
COLOURLESS CRYSTALS

PHYSICAL DANGERS:


CHEMICAL DANGERS:
The substance decomposes on heating producing toxic and corrosive fumesincludinghydrogen chloride (see ICSC 0163).

OCCUPATIONAL EXPOSURE LIMITS:
TLV not established.
MAK not established.


ROUTES OF EXPOSURE:
The substance can be absorbed into the body by ingestion.

INHALATION RISK:
A harmful concentration of airborne particles can be reached quickly when dispersed.

EFFECTS OF SHORT-TERM EXPOSURE:
The substance is irritating to the skin , the respiratory tract , and is severely irritating to the eyes .

EFFECTS OF LONG-TERM OR REPEATED EXPOSURE:

PHYSICAL
PROPERTIES

Decomposes below boiling point at 200°C
Melting point: 114-116°C
Relative density (water = 1): 1.57
Solubility in water, g/100 ml at 25°C: 0.79
Vapour pressure, Pa at 25°C: 0.0045
Octanol/water partition coefficient as log Pow: 2.21

ENVIRONMENTAL
DATA

The substance is harmful to aquatic organisms. This substance does enter the environment under normal use. Great care, however, should be given to avoid any additional release, e.g. through inappropriate disposal.

N O T E S

Carrier solvents used in commercial formulations may change physical and toxicological properties. If the substance is formulated with solvents also consult the ICSCs of these materials.

ADDITIONAL INFORMATION



ICSC: 0139 DICAMBA
(C) IPCS, CEC, 1994
IMPORTANT LEGAL NOTICE: Neither NIOSH, the CEC or the IPCS nor any person acting on behalf of NIOSH, the CEC or the IPCS is responsible for the use which might be made of this information. This card contains the collective views of the IPCS Peer Review Committee and may not reflect in all cases all the detailed requirements included in national legislation on the subject. The user should verify compliance of the cards with the relevant legislation in the country of use. The only modifications made to produce the U.S. version is inclusion of the OSHA PELs, NIOSH RELs and NIOSH IDLH values.
Top