Latent hypoxia

Latent hypoxia occurs when a diver under pressure has a tissue oxygen concentration that is sufficient to support consciousness at that pressure, but insufficient at surface pressure. This problem is associated with freediving blackout and the presence of hypoxic breathing gas mixtures in underwater breathing apparatus, particularly in diving rebreathers.

Latent hypoxia affects the diver on ascent

The term latent hypoxia strictly refers to the situation while the potential victim is still conscious, but is also loosely applied to the consequential blackout, which is a form of hypoxic blackout also referred to as blackout of ascent or deep water blackout, though deep water blackout is also used to refer to the final stage of nitrogen narcosis.[1]

Mechanism

Oxygen-Haemoglobin dissociation curves

The minimum tissue and venous partial pressure of oxygen which will maintain consciousness is about 20 millimetres of mercury (27 mbar).[2] This is equivalent to approximately 30 millimetres of mercury (40 mbar) in the lungs.[3] Approximately 46 ml/min oxygen is required for brain function. This equates to a minimum arterial ppO2 of 29 millimetres of mercury (39 mbar) at 868 ml/min cerebral flow.[2]

An ascent blackout, or deep water blackout, is a loss of consciousness caused by cerebral hypoxia on ascending from a deep freedive or breath-hold dive, typically of ten metres or more when the swimmer does not necessarily experience an urgent need to breathe and has no other obvious medical condition that might have caused it,[4][5][6][7] or from a dive using underwater breathing apparatus using a breathing gas which has too low an oxygen fraction to support consciousness at the surface. Breath-hold victims typically black out close to the surface, sometimes even as they break surface and have been seen to approach the surface without apparent distress only to sink away. Breath-hold victims are usually established practitioners of deep breath-hold diving, are fit, strong swimmers and have not experienced problems before. Blackout by this mechanism may occur even after surfacing from depth and breathing has commenced if the inhaled oxygen has not yet reached the brain and may be referred to as a surface blackout.[8] Divers ascending using breathing apparatus typically ascend at slower ascent rates to avoid decompression sickness, and the depth at which consciousness is lost tends to follow the oxygen partial pressure of the breathing gas.

The partial pressure of oxygen in the air in the lungs controls the oxygen loading of blood. A critical pO2 of 30 millimetres of mercury (40 mbar) in the lungs will sustain consciousness when breathing is resumed after a breath-hold dive. This is about 4% oxygen in the lungs and 45% oxygen saturation of the arterial blood. At 30 msw (4 bar), 2% by volume oxygen in the lung gas gives a pO2 of 60 millimetres of mercury (80 mbar). At 10 msw (2 bar), for the same 2% oxygen, the pO2 would be 30 millimetres of mercury (40 mbar), i.e. marginal. At the surface the same 2% oxygen drops to 15 millimetres of mercury (20 mbar), ignoring metabolic use.[3]

Consequences

The usual consequence, if the airway is not protected, is drowning. A breath-hold diver who has blacked out and has been promptly returned to the surface, will usually regain consciousness within seconds. While the diver is still unconscious underwater, they are at high risk of drowning. While unconscious the diver has lost voluntary bodily control, but still has protective reflexes that protect the airway. One of these is laryngospasm, which closes the larynx, to preventing water from entering the lungs. After some time a laryngospasm will relax and the airway will open, which may result in water ingress if the diver is still underwater. If the diver has reached the surface, and the divers face is kept above water, when the laryngospasm relaxes spontaneous breathing will often resume.[9] The laryngospasm will eventually relax, and if the diver is still underwater then water will enter the airway and may reach the lungs which will cause complications if resuscitation is successful, and secondary drowning is possible.[9] The time between loss of consciousness and death varies considerably depending on a number of factors but can be as little as two and a half minutes.[10]

If the diver's airway is protected by a full-face mask or diving helmet, the immediate risk is death by asphyxiation, which can occur within a few minutes of cessation of breathing. If the diver sinks and the pressure increases sufficiently, the gas may become capable of supporting consciousness again, but the problem of latent hypoxia remains until a higher oxygen content gas is provided. If the diver is on surface supply, a prompt switch of gases may be sufficient to restore consciousness, and this may also apply to a scuba diver if immediate and appropriate action is taken by another diver. Immediate surfacing of a hypoxic diver using underwater breathing apparatus presents the risk of decompression illness from lung barotrauma or decompression sickness, and the risk depends on the pressure exposure history of the diver.

Scope of risk

Open circuit scuba and surface supplied diving using hypoxic breathing mixtures to avoid oxygen toxicity
Breathing mixtures for diving must limit partial pressure of oxygen to avoid the risk of acute oxygen toxicity, Recreational technical divers generally limit partial pressure of oxygen at the maximum planned depth of a dive to approximately 1.4 bar. When diving to depths below 57 m this requires the use of breathing gases with less than 21% oxygen. Gases with less than about 0.16 bar partial pressure of oxygen are considered insufficient to reliably maintain consciousness, so for depths below about 77 m the breathing gas which is safe to breathe at depth is not considered safe to breathe at the surface, and this effect increases with depth. At 130 m the richest gas mix acceptable would be about 10% oxygen. The depth at which this provides 0.16 bar pO2 is about 6 m, so there is a high probability of loss of consciousness if this gas is used shallower than 6 m To reduce this risk, divers will use a travel gas which is suitable for the first part of descent, and switch to bottom gas when it is convenient and safe to breathe it. On the ascent, oxygen rich gases are valuable for accelerating decompression, so there is an additional reason to switch. Unless there is insufficient overlap in safe depth range for decompression gas and bottom gas, the same gas can be used for travel and decompression, which reduces the number of cylinders that must be carried. Failure to switch gas at the required depth can lead to blackout. Surface supplied divers may be required to work at maximum depth for longer and the partial pressure of oxygen may be limited to reduce pulmonary oxygen toxicity, so the discrepancy in oxygen content when surfacing may be greater, however in this case gas switching is controlled by the surface personnel, and the diver's airway is protected by the full-face mask or helmet, and the surface personnel can monitor the status of the diver on the voice communications system, so the overall risk is reduced in comparison with scuba.
Rebreather diving
During ascent at a rate where oxygen addition to the loop does not adequately compensate for partial pressure reduction due to decreasing ambient pressure, the oxygen concentration in the breathing loop can drop below the level required to support consciousness.
Freediving
During breath-hold diving there is no additional breathing gas available during the ascent. If the diver stays down long enough to use up the available oxygen to the extent where tissue concentration has dropped below a level sufficient to support consciousness at surface pressure, there is a very high risk of blackout before the surface can be reached.

Management

Avoidance

  • In open circuit diving using underwater breathing apparatus, the diver must switch to a breathing mixture with sufficient oxygen fraction to maintain an acceptable partial pressure during the next stage of ascent. This adjustment may be done as many times as is necessary and should be scheduled in the dive plan.
  • Semi-closed circuit rebreathers may be flushed to increase oxygen fraction in the loop before and during ascent.
  • Closed circuit rebreathers can have oxygen added to the loop either manually or automatically, to maintain the desired oxygen partial pressure set-point during ascent.
  • Freedivers can only avoid getting into a situation where latent hypoxia occurs. Once oxygen levels reach this point they will probably lose consciousness during the ascent and are at a high risk of drowning. Ensuring that they are positively buoyant in the event of blackout will give them a chance of recovery if they reach the surface.

Rescue

First aid and medical treatment

References

  1. Pollock, Neal W. (25 April 2014). "Loss of Consciousness in Breath-Holding Swimmers". Fact Sheets, Water Safety. National Drowning Prevention Alliance (NDPA.org). Retrieved 17 January 2017.
  2. Stec, A. A.; Hull, T. R., eds. (2010). "4.2 Asphyxia, hypoxia and asphyxiant fire gases". Fire Toxicity. Woodhead Publishing in materials. Part II: Harmful effects of fire effluents. Elsevier. pp. 123–124. ISBN 9781845698072. Retrieved 27 January 2017.
  3. Lindholm, Peter (2006). Lindholm, P.; Pollock, N. W.; Lundgren, C. E. G. (eds.). Physiological mechanisms involved in the risk of loss of consciousness during breath-hold diving (PDF). Breath-hold diving. Proceedings of the Undersea and Hyperbaric Medical Society/Divers Alert Network 2006 June 20–21 Workshop. Durham, NC: Divers Alert Network. p. 26. ISBN 978-1-930536-36-4. Retrieved 24 January 2017.
  4. Brubakk, A. O.; Neuman, T. S. (2003). Bennett and Elliott's physiology and medicine of diving, 5th Rev ed. United States: Saunders Ltd. p. 800. ISBN 0-7020-2571-2.
  5. Lindholm P, Pollock NW, Lundgren CEG, eds. (2006). Breath-hold diving. Proceedings of the Undersea and Hyperbaric Medical Society/Divers Alert Network 2006 June 20–21 Workshop. Durham, NC: Divers Alert Network. ISBN 978-1-930536-36-4. Retrieved 2008-07-21.CS1 maint: multiple names: authors list (link) CS1 maint: extra text: authors list (link)
  6. Elliott, D. (1996). "Deep Water Blackout". South Pacific Underwater Medicine Society Journal. 26 (3). ISSN 0813-1988. OCLC 16986801. Retrieved 2008-07-21.
  7. Campbell, Ernest (1996). "Free Diving and Shallow Water Blackout". Diving Medicine Online. scuba-doc.com. Retrieved 24 January 2017.
  8. Lane, Jordan D. (2017). "Drowning Deaths From Unsupervised Breath Holding: Separating Necessary Training From Unwarranted Risk". Military Medicine. Association of Military Surgeons of the U.S. 182 (January/February): 1471–. doi:10.7205/MILMED-D-16-00246. Retrieved 26 January 2016.
  9. Etzel, Cliff (18 October 2001). "Rescue procedures for Freediver Blackout". Freediving. DeeperBlue. Retrieved 24 January 2017.
  10. Craig, AB Jr. (1976). "Summary of 58 cases of loss of consciousness during underwater swimming and diving". Med Sci Sports. 8 (3): 171–175. doi:10.1249/00005768-197600830-00007. PMID 979564.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.