Radioactive iodine uptake test

The radioactive iodine uptake test, is a type of scan used in the diagnosis of thyroid problems, particularly hyperthyroidism. It is entirely different from radioactive iodine therapy (RAI therapy), which uses much higher doses to destroy cancerous cells. The RAIU test is also used as a follow up to RAI therapy to verify that no thyroid cells survived, which could still be cancerous.[1]

Radioactive iodine uptake test
Medical diagnostics
Thyroid scan with Iodine-123 for evaluation of hyperthyroidism.
SynonymsRAIU test
ICD-9-CM92.01
OPS-301 code3-701

The patient swallows a radioisotope of iodine in the form of capsule or fluid, and the absorption (uptake) of this radiotracer by the thyroid is studied after 4–6 hours and after 24 hours with the aid of a scintillation counter. The dose is typically 0.15–0.37 MBq (4–10 μCi) of 131I iodide, or 3.7–7.4 MBq (100–200 μCi) of 123I iodide.[2] The RAIU test is a reliable measurement when using a dedicated probe with a reproducibility of 1 percent and a 95%-least-significant-change of 3 percent.[3]

The normal uptake is between 15 and 25 percent, but this may be forced down if, in the meantime, the patient has eaten foods high in iodine, such as dairy products and seafood.[4] Low uptake suggests thyroiditis, high uptake suggests Graves' disease,[5] and unevenness in uptake suggests the presence of a nodule.

123I has a shorter half-life than 131I (a half day vs. 8.1 days), so use of 123I exposes the body to less radiation, at the expense of less time to evaluate delayed scan images.[6] Furthermore, 123I emits gamma radiation, while 131I emits gamma and beta radiation.[7]

Contraindications

The test is inappropriate for patients who are pregnant or breastfeeding.[5]

Additional images

References

  1. ThyCa: Thyroid Cancer Survivors' Association, Inc., Radioactive Iodine (RAI).
  2. Kwee, Sandi A.; Coel, Marc N.; Fitz-Patrick, David (2007). Eary, Janet F.; Brenner, Winfried (eds.). Iodine-131 Radiotherapy for Benign Thyroid Disease. Nuclear Medicine Therapy. CRC Press. p. 172. ISBN 978-0-8247-2876-2.
  3. Pelletier-Galarneau, Matthieu; Martineau, Patrick; Klein, Ran; Henderson, Matthew; Zuckier, Lionel S. (January 2018). "Reproducibility of radioactive iodine uptake (RAIU) measurements". Journal of Applied Clinical Medical Physics. 19 (1): 239–242. doi:10.1002/acm2.12217. ISSN 1526-9914. PMC 5768031. PMID 29165912.
  4. M. Sara Rosenthal. The Thyroid Sourcebook. McGraw-Hill, 2008. Page 140.
  5. WebMD article on RAIU test.
  6. Ain, Kenneth; Rosenthal, M. Sara (2010-08-19). The Complete Thyroid Book, Second Edition. McGraw-Hill Professional. pp. 57–. ISBN 978-0-07-174348-8. Retrieved 18 July 2011.
  7. Pilling, Gwen (1999-06-24). Salters higher chemistry. Heinemann. pp. 132–. ISBN 978-0-435-63098-0. Retrieved 18 July 2011.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.