Hounsfield scale

The Hounsfield scale /ˈhnzˌfld/, named after Sir Godfrey Hounsfield, is a quantitative scale for describing radiodensity. It is frequently used in CT scans, where its value is also termed CT number.

Definition

The Hounsfield unit (HU) scale is a linear transformation of the original linear attenuation coefficient measurement into one in which the radiodensity of distilled water at standard pressure and temperature (STP) is defined as zero Hounsfield units (HU), while the radiodensity of air at STP is defined as -1000 HU. In a voxel with average linear attenuation coefficient , the corresponding HU value is therefore given by:

where and are respectively the linear attenuation coefficients of water and air.

Thus, a change of one Hounsfield unit (HU) represents a change of 0.1% of the attenuation coefficient of water since the attenuation coefficient of air is nearly zero.

It is the definition for CT scanners that are calibrated with reference to water.

Rationale

The above standards were chosen as they are universally available references and suited to the key application for which computed axial tomography was developed: imaging the internal anatomy of living creatures based on organized water structures and mostly living in air, e.g. humans.

Value in parts of the body

The Hounsfield scale applies to medical-grade CT scans but not to cone beam computed tomography (CBCT) scans.[1]

SubstanceHU
Air −1000
Fat −120 to −90[2]
Soft tissue on contrast CT +100 to +300
BoneCancellous+300 to +400[3]
Cortical+1800 to +1900[3]
Subdural hematomaFirst hours+75 to +100[4]
After 3 days+65 to +85[4]
After 10-14 days+35 to +40[5]
Other bloodUnclotted+13[6] to +50[7]
Clotted+50[8] to +75[6][8]
Pleural effusionTransudate+2 to +15 [9]
Exudate+4 to +33[9]
Other fluidsChyle −30[10]
Water 0
Urine -5 to +15[2]
Bile -5 to +15[2]
CSF +15
Abscess / Pus 0[11] or +20[12], to +40[12] or +45[11]
Mucus 0[13] - 130[14] ("high attenuating" at over 70 HU)[15][16]
ParenchymaLung -700 to −600[17]
Kidney +20 to +45[2]
Liver 60 ± 6[18]
Lymph nodes +10 to +20[19]
Muscle +35 to +55[2]
Thymus
  • +20 to +40 in children[20]
  • +20 to +120 in adolescents[20]
White matter +20 to +30
Grey matter +37 to +45
GallstoneCholesterol stone+30 to +100[21]
Bilirubin stone+90 to +120[21]
Foreign body[22] Windowpane glass+500
Aluminum, tarmac, car window glass, bottle glass, and other rocks+2,100 to +2,300
Limestone+2,800
Copper+14,000
Silver+17,000
Steel+20,000
Gold, steel, and brass+30,000 (upper measurable limit)
Earwax<0

A practical application of this is in evaluation of tumors, where, for example, an adrenal tumor with a radiodensity of less than 10 HU is rather fatty in composition and almost certainly a benign adrenal adenoma.[23]

See also

References

  • Feeman, Timothy G. (2010). The Mathematics of Medical Imaging: A Beginner's Guide. Springer Undergraduate Texts in Mathematics and Technology. Springer. ISBN 978-0387927114.

Notes

  1. De Vos, W.; Casselman, J.; Swennen, G.R.J. (June 2009). "Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature". International Journal of Oral and Maxillofacial Surgery. 38 (6): 609–625. doi:10.1016/j.ijom.2009.02.028. PMID 19464146.
  2. Page 83 in: Herbert Lepor (2000). Prostatic Diseases. W.B. Saunders Company. ISBN 9780721674162.
  3. Birur, NPraveen; Patrick, Sanjana; Gurushanth, Keerthi; Raghavan, AShubhasini; Gurudath, Shubha (2017). "Comparison of gray values of cone-beam computed tomography with hounsfield units of multislice computed tomography: An in vitro study". Indian Journal of Dental Research. 28 (1): 66–70. doi:10.4103/ijdr.IJDR_415_16. ISSN 0970-9290. PMID 28393820.
  4. Fig 3 in: Rao, Murali Gundu (2016). "Dating of Early Subdural Haematoma: A Correlative Clinico-Radiological Study". Journal of Clinical and Diagnostic Research. 10 (4): HC01–5. doi:10.7860/JCDR/2016/17207.7644. ISSN 2249-782X. PMC 4866129. PMID 27190831.
  5. Dr Rohit Sharma and A.Prof Frank Gaillard. "Subdural haemorrhage". Radiopaedia. Retrieved 2018-08-14.
  6. Page 263 in: Robert Fosbinder, Denise Orth (2011). Essentials of Radiologic Science. Lippincott Williams & Wilkins. ISBN 9780781775540.
  7. page 20.17 in: F W Wright (2001). Radiology of the Chest and Related Conditions. CRC Press. ISBN 9780415281416.
  8. page 17 in: Dr. Avital Fast, Dorith Goldsher (2006). Navigating the Adult Spine: Bridging Clinical Practice and Neuroradiology. Demos Medical Publishing. ISBN 9781934559741.
  9. Cullu, Nesat; Kalemci, Serdar; Karakas, Omer; Eser, Irfan; Yalcin, Funda; Boyaci, Fatma Nurefsan; Karakas, Ekrem (2013). "Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion". Diagnostic and Interventional Radiology. 20 (2): 116–20. doi:10.5152/dir.2013.13066. ISSN 1305-3825. PMC 4463296. PMID 24100060.
  10. Page 342 in: Luca Saba, Jasjit S. Suri (2013). Multi-Detector CT Imaging: Principles, Head, Neck, and Vascular Systems, Volume 1. CRC Press. ISBN 9781439893845.
  11. P. Sanchez de Medina Alba, C. Santos Montón, N. Calvo, K. El Karzazi, T. González de la Huebra Labrador, R. Corrales, N. Alegre Borge; Salamanca/ES (2014). "Liver abscesses: where do they come from?A review of the main types of liver abscesses and the correlation between their causes and the radiologic findings". ECR 2014. doi:10.1594/ecr2014/C-1927.CS1 maint: multiple names: authors list (link)
  12. Sasaki, Toru; Miyata, Rie; Hatai, Yoshiho; Makita, Kohzoh; Tsunoda, Koichi (2014). "Hounsfield unit values of retropharyngeal abscess-like lesions seen in Kawasaki disease". Acta Oto-Laryngologica. 134 (4): 437–440. doi:10.3109/00016489.2013.878475. ISSN 0001-6489. PMID 24512428.
  13. K SAGGAR, A AHLUWALIA, P SANDHU, V KALIA (2006). "Mucocoele Of The Appendix" (PDF). Ind J Radiol Imag. 16 (2).CS1 maint: multiple names: authors list (link)
  14. Gaeta, Michele; Vinci, Sergio; Minutoli, Fabio; Mazziotti, Silvio; Ascenti, Giorgio; Salamone, Ignazio; Lamberto, Salvatore; Blandino, Alfredo (2001). "CT and MRI findings of mucin-containing tumors and pseudotumors of the thorax: pictorial review". European Radiology. 12 (1): 181–189. doi:10.1007/s003300100934. ISSN 0938-7994. PMID 11868096.
  15. Subash S Phuyal, Mandeep Kumar MK Garg, Ritesh R Agarwal, Pankaj P Gupta, Arunaloke A Chakrabarti, Manavjit Singh MS Sandhu, Niranjan N Khandelwal (2015-09-02). "High-Attenuation Mucus Impaction in Patients With Allergic Bronchopulmonary Aspergillosis: Objective Criteria on High-Resolution Computed Tomography and Correlation With Serologic Parameters". Current Problems in Diagnostic Radiology.CS1 maint: multiple names: authors list (link)
  16. Agarwal, Ritesh; Sehgal, Inderpaul Singh; Dhooria, Sahajal; Aggarwal, Ashutosh (2016). "Radiologic Criteria for the Diagnosis of High-Attenuation Mucus in Allergic Bronchopulmonary Aspergillosis". Chest. 149 (4): 1109–1110. doi:10.1016/j.chest.2015.12.043. ISSN 0012-3692. PMID 27055707.
  17. Page 379 in: Ella A. Kazerooni, Barry H. Gross (2004). Cardiopulmonary Imaging. 4. Lippincott Williams & Wilkins. ISBN 9780781736558.
  18. page 210 in: Erwin Kuntz, Hans-Dieter Kuntz (2006). Hepatology, Principles and Practice: History, Morphology, Biochemistry, Diagnostics, Clinic, Therapy. Springer Science & Business Media. ISBN 9783540289777.
  19. Page 58 in: G. Maatman (2012). High-Resolution Computed Tomography of the Paranasal Sinuses and Pharynx and Related Regions: Impact of CT identification on diagnosis and patient management. Volume 12 of Series in Radiology. Springer Science & Business Media. ISBN 9789400942776.
  20. Page 488 in: Jean-Claude Givel, Marco Merlini, David B. Clarke, Michael Dusmet (2012). Surgery of the Thymus: Pathology, Associated Disorders and Surgical Technique. Springer Science & Business Media. ISBN 9783642710766.CS1 maint: multiple names: authors list (link)
  21. Rambow A, Staritz M, Wosiewitz U, Mildenburger P, Thelen M, Meyer zum Büschenfelde KH (1990). "Analysis of radiolucent gallstones by computed tomography for in vivo estimation of stone components". Eur J Clin Invest. 20 (4): 475–8. doi:10.1111/j.1365-2362.1990.tb01887.x. PMID 2121509.
  22. Bolliger, Stephan A.; Oesterhelweg, Lars; Spendlove, Danny; Ross, Steffen; Thali, Michael J. (2009). "Is Differentiation of Frequently Encountered Foreign Bodies in Corpses Possible by Hounsfield Density Measurement?". Journal of Forensic Sciences. 54 (5): 1119–1122. doi:10.1111/j.1556-4029.2009.01100.x. ISSN 0022-1198. PMID 19627414.
  23. medscape >Adrenal Adenoma Imaging. Author: Perry J Horwich. Chief Editor: Eugene C Lin. Updated: Apr 21, 2011
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.